HYB-LINE (Hybrid Line)
Issue 4 May 2002
10-893
555-233-123
Any
FAIL
This test can fail due to on-board or off-board problems.
Off-board problems of concern include EXP-INTF faults,
TDM-BUS faults, and faults associated with the tone
detectors/tone generators. Clear all off-board problems before
replacing the board. Keep in mind that a TDM-BUS problem is
usually the result of a faulty board connected to the backplane
or bent pins on the backplane.
1. Look for EXP-INTF errors in the error log. If present, refer
to the EXP-INTF Maintenance documentation.
2. Look for TDM-BUS errors in the error log. If present, refer
to the TDM-BUS Maintenance documentation.
3. Retest the board when the faults from steps 1 and 2 are
cleared.
PASS
The port is correctly using its allocated time slots.
User-reported troubles on this port should be investigated
using other port tests and examining station, trunk, or external
wiring.
0
NO
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is
inserted, an incorrect board is inserted, or an insane board is
inserted.
1. Check to ensure that the board translations are correct.
Use list config, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1,
issue busyout board.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue test board long. This should re-establish the
linkage between the internal ID and the port. If this is not
the case, dispatch to check to ensure that there is a valid
board inserted.
Table 10-324.
TEST #6 NPE Crosstalk Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...