DIG-LINE (Digital Line)
Issue 4 May 2002
10-571
555-233-123
14
FAIL
The primary channel (voice, Information Channel 1 or I1) is not
operating properly. User impact may range from noticing
nothing to not being able to use the port. Check the results of
Voice and Control Channel Local Loop Test (#13). If that test
fails, suspect the Digital Line circuit pack. If that test passes
then replace the terminal. If both tests fail and component
replacement does not change the results, then:
1. Run circuit pack tests to check the tone generator circuit
pack and the Tone Detector circuit pack using the test
board PCSSpp command.
2. Resolve any problems that are detected on the Tone
Generator circuit pack or Tone Detector circuit pack.
3. If the Tone Generator and Tone Detector circuit pack are
functioning properly, and the tests still fail, escalate the
problem.
1015
ABORT
The system will not allow this test to be run because the
station is/has not been busied out. Busy out the station with
the busyout station command.
Table 10-211.
TEST #1201 Digital Terminal Remote Loop Around Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...