E-DIG-STA (Emulated Digital Line)
Issue 4 May 2002
10-731
555-233-123
Station Lamp Updates Test (#16)
This test lights all lamps on the terminal as specified. The lamp updates will run
only if the station is in-service. The status of the station is checked and the lamp
updates are blocked from taking place if the station is not in the in-service state.
This test does not affect the status of the Message Waiting lamp.
Table 10-273.
TEST #16 DIG-LINE Station Lamp Updates Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
1
ABORT
System technician may have busied out the port.
1. Look in the Error Log for Error Type 18 (port busied out) for
this port. If this error type is present, then release the port
with the release station <extension> command and run
the test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals a maximum of 5
times.
3
ABORT
Station may be in ready-for-service or out-of-service state.
1. Use the status station command to verify state of station.
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals a maximum of 5
times.
1000
ABORT
System resources required to run this test are not available.
The port is busy with a valid call. Use display port PCSSpp to
determine the station extension or attendant number of the
port. Use status station or status attendant to determine the
service state of the port. If the service state indicates that the
port is in use, then the port is unavailable for certain tests. Wait
until the port is idle before retesting. Attendants are always in
use (off-hook) if the handset is plugged in and the port is not
busied out.
1. If the port status is idle, then retry the command at
1-minute intervals a maximum of 5 times.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...