Maintenance Object Repair Procedures
555-233-123
10-1960
Issue 4 May 2002
Table 10-701.
TN2501AP LEDs
LED
Behavior
Description
Red
On solid
Circuit pack failure or a major or minor on-board alarm
Green
On solid
Firmware is self-downloading to the circuit pack or testing in
progress.
Amber
On solid
Firmware is self-downloading to the circuit pack.
!
CAUTION:
You can lose the resident firmware image file if you reset the
circuit pack during firmware download. If this happens, FTP a
new firmware image file to the VAL circuit pack and perform
the Firmware download procedure again.
Amber
Fast flash
(100ms on/
100ms off)
Occurs during circuit pack insertion or circuit pack reset which the
announcement files are being copied from FLASH to RAM. If you
reset the circuit pack during this time, your announcement files
remain intact.
Amber
Slow flash
(200ms on/
200ms off)
Flashes during autosave while copying announcement files from
RAM to FLASH.
!
CAUTION:
You can lose the announcements on the circuit pack if you
reset it during an autosave.
LINK
On/off
Active ethernet link
TRMT
Intermittent
Transmit
RCV
Intermittent
Receive
100M
On/off
Off = 10MB ethernet connection
On = 100MB ethernet connection
FDX
On/off
Off = half-duplex connection
On = full duplex connection
COL
On/off
Off = no collision detected
On = collisions detected
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...