FL-DATA (Flash Data Consistency)
Issue 4 May 2002
10-835
555-233-123
44
FAIL
The update files, load vintages, and announcements are
different in both SPEs. The Active SPE has the most
current update file and announcements.
45
FAIL
The update files, load vintages, translations, and
announcements are different in both SPEs. The Active
SPE has the most current update file, translations, and
announcements.
46
FAIL
The update files, load vintages, translations, and
announcements are different in both SPEs. The Active
SPE has the most current update file and announcements,
and the Standby SPE has the most current translations.
1. Follow the procedures for Error Code 4 to get the
correct load vintage. Be sure to save the
announcements. After running test card-mem long,
check for Error Codes 32 or 64. Follow the recovery
procedure under the applicable error code.
48
FAIL
The update files and announcements are different in both
SPEs. The Active SPE has the most current update file,
and the Standby SPE has the most current
announcements.
1. Follow the procedures for Error Code 40.
49
FAIL
The update files, translations, and announcements are
different in both SPEs. The Active SPE has the most
current update file and translations, and the Standby SPE
has the most current announcements.
50
FAIL
The update files, translations, and announcements are
different in both SPEs. The Active SPE has the most
current update file, and the Standby SPE has the most
current translations and announcements.
1. Follow the procedures for Error Code 41.
Table 10-303.
TEST #421 Flash Data Consistency Check Test — Continued
Error Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...