Maintenance Object Repair Procedures
555-233-123
10-658
Issue 4 May 2002
Misframe Alarm Inquiry Test (#145)
Misframe Alarm indicates that framing bits observed on a DS1 Interface circuit
pack are in error. Misframe Alarm Inquiry Test queries the total number of
misframes that occurred on a DS1 Interface circuit pack since the last inquiry.
When the DS1 Interface circuit pack detects a misframe error, it will increase its
misframe counter by 1. If the counter reaches the threshold, a
MISFRAME-COUNT message is automatically sent to the switch maintenance
software. After the maintenance software receives the MISFRAME-COUNT
message, the Misframe Alarm Inquiry Test is initiated to collect the misframe
counts from the DS1 Interface circuit pack.
When the threshold of misframes is reached, if the DS1 Interface circuit pack is
supplying the system synchronization source, then a switching synchronization
source message is sent to the TDM Bus Clock. See TDM-BUS (TDM Bus)
Maintenance documentation for details. A Minor alarm against the DS1 Interface
circuit pack is raised, but all trunks of the DS1 Interface circuit pack are still in the
in-service state.
PASS
No Slip alarm is detected on the DS1 Interface circuit pack.
0
NO BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is
inserted, an incorrect board is inserted, or an insane board is
inserted.
1. Check to ensure that the board translations are correct.
Use the add ds1 UUCSS command to administer the
DS1 interface if it is not already administered.
2. If board was already administered correctly, check the
error log to determine if the board is hyperactive. If this is
the case, the board is shut down. Reseating the board will
re-initialize the board.
3. If the board was found to be correctly inserted in step 1,
issue the busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the link between the internal ID and
the port.
Table 10-241.
TEST #144 Slip Alarm Inquiry Test — Continued
Error
Code
Test Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...