Maintenance Object Repair Procedures
555-233-123
10-8
Issue 4 May 2002
The environment maintenance strategy to be used depends on both the cabinet
configuration and the type of powering. Refer to the “DC-POWER (Single-Carrier
Cabinet Power)” information for environment maintenance strategy.
In a DC-powered multicarrier cabinet system, the AC-POWER maintenance
object still exists, but serves no functional purpose. Because the system cannot
determine the type of powering provided, all AC-POWER tests should always
either pass or abort.
Error Log Entries and Test to Clear Values
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the following table. By clearing
error codes associated with the AC Power Query Test, for example, you may also
clear errors generated from other tests in the testing sequence.
Table 10-3.
AC Power Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test environment P sh r 1
513
Any
AC Power Query Test
(#78)
WARNING
OFF
test environment P sh r 1
Table 10-4.
System Technician-Demanded Tests: AC-Power
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
Battery & Battery Charger Query Test (#5) (a)
X
X
ND
AC Power Query Test (#78)
X
X
ND
Power Unit Query Test (carrier E) (#127) (b)
X
X
ND
Power Unit Query Test (carrier D) (#127) (b)
X
X
ND
Power Unit Query Test (carrier A) (#127) (b)
X
X
ND
Power Unit Query Test (carrier B) (#127) (b)
X
X
ND
Power Unit Query Test (carrier C) (#127) (b)
X
X
ND
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...