CUST-ALM (Customer-Provided Alarming Device)
Issue 4 May 2002
10-477
555-233-123
CUST-ALM (Customer-Provided
Alarming Device)
The system provides customers a way to connect their own alarm indication
device to a switch. The CUST-ALM maintenance object represents this
Customer-Provided Alarming Device (CPAD). When an alarm occurs at least to
the level to which the CPAD is administered, the CPAD in the Processor Port
Network (PPN) and in the Expansion Port Network (EPN) are activated. The
CPAD is administered by the Maintenance-Related System Parameters Form
(CPE Alarm Activation Level field). The CPAD is connected to the
Maintenance/Tape Processor in the PPN (in a High or Critical Reliability system,
the CPAD is connected to both Maintenance/Tape Processors) and to the EPN
Maintenance circuit pack in the EPN. The valid levels to which to set the CPE
Alarm Activation Level are: none, warning, minor, or major. The CPAD is also
activated within a cabinet whenever Emergency Transfer is invoked within that
cabinet. The CUST-ALM MO is not maintained by the system, and does not
generate any alarms. If a problem is suspected with the CPAD, it may be tested
using the test customer-alarm command, which activates the device by closing
the relay on either the Maintenance/Tape Processor or the EPN Maintenance
circuit pack (whichever is specified) for 1 minute. In a High or Critical Reliability
system, the CPAD on the PPN is connected to the Maintenance/Tape Processor
on both carrier A and carrier B, and the test customer-alarm command can
specify which Maintenance/Tape Processor should close its relay. The repeat
parameter may be used to close the relay for a longer length of time (5 minutes is
the suggested repeat value).
The CPAD is also activated within a cabinet whenever Emergency Transfer is
invoked within that cabinet. The CUST-ALM MO is not maintained by the system,
and does not generate any alarms. If a problem is suspected with the CPAD, it
may be tested using the test customer-alarm command, which activates the
device by closing the relay on either the Maintenance/Tape Processor or the EPN
Maintenance circuit pack (whichever is specified) for 1 minute. In a High or Critical
Reliability system, the CPAD on the PPN is connected to the Maintenance/Tape
Processor on both carrier A and carrier B, and the test customer-alarm
command can specify which Maintenance/Tape Processor should close its relay.
The repeat parameter may be used to close the relay for a longer length of time (5
minutes is the suggested repeat value).
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to Run
1
1
Where PC is an appropriate port network number and carrier (for a High or Critical Reliability
system, specify 1a or 1b).
Full Name of MO
CUST-ALM
none
test customer-alarm PC
Customer-Provided Alarming Device
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...