DIOD-TRK (DIOD Trunk) [G1.2SE]
Issue 4 May 2002
10-597
555-233-123
LOOP START OPERATION
Idle State - Tip = ground, Ring = CO Battery
A. Outgoing Call
1. PBX Off-Hook (Seize Message): Closes the Tip-Ring Loop
a. CO Response: DC loop c Dial tone
2. PBX On-Hook (Drop Message): Open Tip-Ring loop, no loop current
a. CO Response: CO goes to idle state (see Note)
B. Incoming Call
1. CO Applies Ringing Voltage
a. PBX Response: Detect ringing current
2. PBX Off-Hook (Answer Message): Close loop
a. CO Response: Trip ringing, provide loop current
3. PBX On-Hook (Drop Message): Open Tip-Ring loop, no loop current
a. CO Response: CO goes to idle state (see Note)
C. Direct Inward Dialing (DID)
1. CO Applies Ringing Voltage
a. PBX Response: Detect ringing current and close loop
b. CO Response: Send DTMF digits
c. PBX Response: Acknowledge of Number dialed and open loop
2. PBX Off-Hook (Answer Message): Close loop
a. CO Response: Trip ringing, provide loop current
3. PBX On-Hook (Drop Message): Open Tip-Ring loop, no loop current
a. CO Response: CO goes to idle state (see Note)
NOTE:
CO does not normally provide an On-Hook (Disconnect) signal.
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...