CO-TRK (CO Trunk)
Issue 4 May 2002
10-461
555-233-123
1004
ABORT
The port has been seized by a user for a valid call. Use status
trunk to determine when the port is available for testing.
1. Retry the command at 1 minute intervals for a maximum of
5 retries.
2. If the test continues to abort and the port is not in use,
escalate the problem.
1005
ABORT
Trunk has been administered as incoming-only; transmission
tests can only be run on outgoing trunks.
1115
ABORT
The near end test line on the TN771 circuit pack could not be
allocated.
1. Verify that the TN771 circuit pack is in service and that port
1 is administered and in service with the status port
command.
2. Retry the command at 1-minute intervals for a maximum of
5 times.
1900
ABORT
The test completion message was not received from the
TN771 circuit pack.
1. Test the TN771 circuit packs.
1901
ABORT
This error occurs when the TN771 circuit pack uplinks a
message that is not the proper response for this test. The
anticipated uplink messages are seize, ring or answer.
1. Verify that the Trunk is administered properly.
1905
ABORT
Intercept tone detected from far end.
1. Get the test line data and verify it with the far end. Dial the
test number manually to see if the TTL is reached. If it is
not, then either the number is wrong, or the far end is
administered incorrectly.
1906
ABORT
Reorder tone detected from far end.
1. See actions for error code 1905.
1907
ABORT
Other unexpected tone detected from far end.
1. See actions for error code 1905.
1913
ABORT
Audible Ring detected from far end.
1. See actions for error code 1905.
1914
ABORT
Unidentified interrupted tone detected from far end.
1. See actions for error code 1905
Table 10-170.
TEST #844-848 Transmission Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...