Maintenance Object Repair Procedures
555-233-123
10-162
Issue 4 May 2002
2000
ABORT
Response to the test request was not received within the
allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this
test.
ABORT
Internal System Error.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1 to 254
FAIL
Test failed. The error code indicates the number of byte count
errors found by the Tone Detector.
1. Reset the circuit pack via the reset board PCSS
command and then run this test again. If the test
continues to fail, replace the circuit pack (see Warning).
2. If there are recurring alarms on this port caused by this
test failing, replace the circuit pack even if Step 1 works
(see Warning).
!
WARNING:
Replacing the circuit pack results in loss of integrated
announcements. Refer to “General Notes” near the
beginning of this Maintenance procedure.
Table 10-53.
TEST #206 Playback Speech Memory Array (PSMA) Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page