ETH-PT (Control LAN Ethernet)
Issue 4 May 2002
10-749
555-233-123
Session Status Test (#1286)
This non-destructive test determines the status of all Ethernet port sessions. This
test queries the system software on port session status.
2500
ABORT
Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
FAIL
Link integrity lost due to problem with attachment of Ethernet
cable to the port.
1. Repeat the test.
2. If the test fails, verify that the cable properly is secured to
Ethernet port and to the bus.
3. Verify the CLAN circuit pack link integrity LED is glowing.
4. Retry the test.
5. If problem persists, refer to Ethernet Local Looparound Test
(#1278) repair procedures.
PASS
The Ethernet Link Integrity Test (#1282) detects good
connections.
If the system software indicates that:
Then the switch:
All port sessions are up (ALL UP)
Raises no alarm, or retires alarm
Some port sessions are up (SOME UP)
Raises WARNING alarm
All port sessions are down (ALL DOWN)
Raises MINOR alarm
Table 10-282.
TEST #1282 Link Integrity Inquiry Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...