Maintenance Object Repair Procedures
555-233-123
10-142
Issue 4 May 2002
Announcement Checksum Test (#209)
Associated with every recorded announcement is a checksum. In this test, the SP
checks a stored global checksum covering all recorded announcements against a
calculated one and returns the results to the maintenance system. If the global
checksum failed, maintenance requests the SP to check each individual
announcement’s checksum.
If the test fails, then it returns the total number of defective announcements found.
In addition, associated with each failure is an error in the Error Log (Error Type
14). The Aux Data indicates the number of the first defective announcement
found. This number corresponds to the announcement numbers on the
announcement form. The extension relating to the announcement can be
determined by the display announcement command.
Table 10-47.
TEST #209 Announcement Checksum Test
Error
Code
Test
Result
Description/Recommendation
0
ABORT
An error code of 0 indicates that the announcement file has
been corrupted due to a hardware fault in the TN750 board.
Follow step #7 under “General Notes” at the beginning of this
section.
1023
ABORT
There are no announcements currently recorded on the circuit
pack.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...