PDMODULE, TDMODULE (Data Module)
Issue 4 May 2002
10-1191
555-233-123
Information and Control Channel Local Loop Test
(#13)
This is a set of four tests that check the operation of the information and control
channels used between the SPE and the Digital Line port circuit.
NOTE:
This is an Internal Loop Around test only and does not check building wiring.
Use Test #175 for external loop around tests to the data module.
2020
ABORT
The test did not run due to a previously existing error on the
specific port or a more general circuit pack error.
1. Examine Error Log for existing errors against this port or the
circuit pack and attempt to diagnose the previously existing
error.
2100
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at one-minute intervals a maximum of 5
times.
2500
ABORT
Internal System Error.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1,2
FAIL
The NPE of the tested port was found to be transmitting in Error
Log. This causes noisy and unreliable connections. Failure Code
1 indicates that the Crosstalk Test failed on the primary channel.
Failure Code 2 indicates that the Crosstalk Test failed on the
secondary channel.
1. Replace the circuit pack.
PASS
The port is correctly using its allocated time slots.
1. To be sure that this is not an intermittent problem, repeat this
test up to a maximum of 10 times and verify that it continues
to pass.
2. If complaints still exist, examine the data module,
connections, and wiring.
Table 10-445.
TEST #9 NPE Crosstalk Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...