Maintenance Object Repair Procedures
555-233-123
10-98
Issue 4 May 2002
1006
ABORT
This port has been busied out by command or taken
out-of-service by the failure of the NPE Crosstalk Test.
1. Look in the Error Log for Error Type 18 (port busied out) for
this port. If this error is present, then release the port with
the release station extension command and run the test
again.
2. Look in the Error Log for Error Type 1025 (NPE Crosstalk
Test failed) for this port. If this error is present, then
investigate the errors associated with the NPE Crosstalk
Test (#6) first.
3. Make sure that the terminal is connected and in service,
and then retest.
ABORT
Could not allocate the necessary system resources to run this
test.
2000
ABORT
Response to the test request was not received within the
allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1
FAIL
This does not indicate a hardware problem. The switchhook
audit failed, and the other updates were not performed
because of this failure. This condition may occur when the
audit is performed at the same time that the terminal
equipment goes off-hook. Use the status station command to
determine when the port is available for testing.
1. When the port becomes available for testing, retry the
command at 1-minute intervals a maximum of 5 times.
5
FAIL
This does not indicate a hardware problem but may indicate an
internal software error. The message waiting lamp update
failed. The translation and ringer updates were not performed
because of this failure.
7
FAIL
The translation update failed. The ringer update was not
performed because of this failure. This does not indicate a
hardware problem but may be an internal software error.
Table 10-34.
TEST #36 Station Status and Translation Audits and Updates Test
— Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...