TDM-BUS (TDM Bus)
Issue 4 May 2002
10-1699
555-233-123
TDM-BUS (TDM Bus)
The TDM Bus consists of a duplicated TDM Bus on each port network (PPN and
EPN): TDM Bus A and TDM Bus B. Each TDM Bus consists of 256 time slots. The
first five time slots on each bus are called the Control Channel. The Control
Channel is active on only one bus at a time in each Port Network. The next 17
time slots are reserved for dedicated tones (that is, dial tone). These time slots are
called the dedicated tone time slots and only one bus at a time carries the
dedicated tones. The rest of the time slots on each bus are for general system use
(that is, phone call).
On system initialization, the Control Channel is on TDM Bus A and the dedicated
tones on TDM Bus B in each Port Network.
Systems with High or Critical Reliability have the ability to set the Control Channel
and Tone Bus to a specific TDM Bus via the set tdm PC command, where P
stands for the Port Network Number and C stands for the TDM Bus A or B (A for
TDM Bus A or B for TDM Bus B). Throughout this document, PC is used to refer
to a TDM Bus.
Terminology:
■
Control Channel Bus - The TDM Bus control channel is on.
■
Non-Control Channel Bus - The TDM Bus control channel is NOT on.
■
Tone Bus - The TDM Bus dedicated tone time slots are on.
■
Non-Tone Bus - The TDM Bus dedicated tone time slots are NOT on.
TDM Bus Fault Detection and Isolation
Procedure
TDM Bus faults are most likely caused by a defective circuit pack connected to the
backplane or bent pins on the backplane. It is possible that a circuit pack can
cause a TDM Bus fault but still exhibit trouble-free operation. For example, the
insertion of an MBUS (Memory Bus) only circuit pack can bend the TDM Bus pins
on the backplane and short two leads together. The four circuit packs that may
cause this problem are the TN770 Memory circuit pack, the TN777 80286
Processor circuit pack, the TN772 Duplication Interface circuit pack, and the
TN777 Network Control circuit pack. The latter exists only on High and Critical
Reliability systems. Since the TDM Bus is a shared resource, automatic
identification of the cause of a TDM Bus fault is difficult. If a TDM Bus problem is
MO Name (in
Alarm Log)
Alarm
Level
Initial Command
to Run
Full Name of MO
TDM-BUS
MAJOR
test tdm P
TDM Bus
TDM-BUS
MINOR
test tdm P
TDM Bus
TDM-BUS
WARNING
test tdm P
TDM Bus
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...