TTR-LEV (TTR Level)
Issue 4 May 2002
10-1829
555-233-123
Hardware Error Log Entries and Test to Clear
Values
!
WARNING:
The Alarm is upgraded to MAJOR if the Base Tone Generator is set to 12
(France).
Notes:
a. Error code 1 does not indicate a current error condition. It indicates that the
number of DTMR ports in service was below the administered threshold,
but is now equal to or greater than the threshold. These errors are typically
generated during boot time or other transitional states when the ports are
being brought into service.
b. The total number of DTMR ports currently in service is below the
administered threshold. To clear the alarm, refer to the repair procedure
described above.
c. Error code 3 does not indicate a current error condition. It indicates that the
number of GPTD ports in service was below the administered threshold,
but is now equal to or greater than the threshold. These errors are typically
generated during boot time or other transitional states when the ports are
being brought into service.
d. The total number of GPTD ports currently in service is below the
administered threshold. To clear the alarm, refer to the repair procedure
describe above.
TTR Level Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm Level
On/Off
Board
Test to Clear Value
1 (a)
1
None
2 (b)
2
WARNING (See
the WARNING
message below)
OFF
3 (c)
3
None
4 (d)
4
WARNING
OFF
5 (e)
5
None
6 (f)
6
WARNING
OFF
7 (g)
7
MAJOR
OFF
8 (h)
8
MINOR
OFF
9 (i)
9
MINOR
OFF
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...