VC-SUMPT
Issue 4 May 2002
10-1987
555-233-123
VC-SUMPT
Each Voice Conditioner Circuit Pack (VC-BD) provides two types of resources:
1. Transcoder Resources that are used for encoding and decoding audio
formats
2. Summer Resources that are used for summing audio formats from different
sources.
The Voice Conditioner Summer ports (VC-SUMPT) are the summer resources on
the VC-BD. There are 8 such ports on a VC-BD.
Error Log Entries and Test to Clear Values
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to
Run
1
1
Where UU is the universal cabinet number (1 for PPN and 2-3 for EPN); C is the carrier
designation (for example, A, B, C, D, or E); SS is the address of the slot in the carrier
where the circuit pack is located (for example, 01, 02, ...); and pp is the two digit port
number (01, 02, 03, ...).
Full Name of MO
VC-SUMPT
MAJ
test port PCSS l r#
Voice Conditioner Summer Port
VC-SUMPT
MIN
test port PCSS l r#
Voice Conditioner Summer Port
VC-SUMPT
WNG
test port PCSS s r#
Voice Conditioner Summer Port
Table 10-714.
VC-SUMPT Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1
Run the short test sequence first. If all test pass, run the long test sequence. Refer to the appropriate
test description and follow the recommended procedures.
0
Any
Any
Any
test port PCSSpp sh r 1
18 (a)
0
busyout port PCSS
WNG
OFF
release port PCSSpp
130 (b)
WNG
ON
test port PCSSpp sh
257 (c)
Any
Control Channel Loop
Test (#52)
MIN
ON
test board PCSSpp 1 r 3
513 (d)
Any
VC Summer Port Local
Loopback Test #(1100)
MIN
ON
test board PCSSpp sh r 3
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...