Maintenance Object Repair Procedures
555-233-123
10-446
Issue 4 May 2002
1004
ABORT
The port was seized by a user for a valid call. Use the display
port PCSSpp command to determine the trunk group/member
number of the port. Use the status trunk command to
determine the service state of the port. If the service state
indicates that the port is in use, then the port is unavailable for
certain tests. You must wait until the port is idle before
retesting.
1. If the port status is idle, retry the command at 1 minute
intervals for a maximum of 5 times.
1005
ABORT
Trunk has been administered as incoming-only; dial tone can
only be obtained on outgoing trunks. This is a normal
condition.
1018
ABORT
Test has been disabled via administration.
1. Verify that the “Maintenance Tests?” field on the Trunk
Group Form is set to “n”. To enable the test, issue the
change trunk-group x command where “x” equals the
number of the trunk group to be tested. Then change the
entry in the “Maintenance Tests?” field on the form to “y.”
2000
ABORT
Response to the test was not received within the allowable
time period.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Table 10-165.
TEST #0 Dial Tone Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...