
ATM-TRK (Circuit Emulation Service Circuit Pack)
Issue 4 May 2002
10-235
555-233-123
20
Loss of pointer:
LOP
ATM framer chip is unable to access the payload part of the signal.
Reset the board (reset board UUCSS).
If the error persists replace the board.
21
Path Signal Error
(PSL)
(STM1/SONET)
The incoming signal payload is not set up for transmission of ATM
data.
Make sure the ATM switch port (or a MUX port, if present between
ATM switch and the ATM-TRK board) is the same as the ATM-TRK
circuit pack’s cable interface.
22
High-level Path
Alarm Indication
Signal:
HP_AIS
The payload is invalid.
Make sure the ATM switch port (or a MUX port, if present between
ATM switch and the ATM-TRK board) is the same as the ATM-TRK
circuit pack’s cable interface.
Run test board UUCSS.
If Test #1259 fails with Error Code 22, connect a fiber back-to-back
in a looped mode (one strand of fiber connecting the transmit
transceiver to the receive transceiver of the board) and see if the
yellow LED flash goes away.
If it does the problem is off-board.
If the yellow LED continues to flash, replace the circuit pack.
23
High-level path
Remote defect
Indicator: HP_RDI
The far-end is detecting a major problem with the signal that this
board is transmitting. The transmitted payload is invalid.
Make sure the ATM switch port (or a MUX port, if present between
ATM switch and the ATM-TRK board) is the same as the ATM-TRK
circuit pack’s cable interface.
Run test board UUCSS command; if the Test #1259 fails with Error
Code 23, connect a fiber back-to-back in a looped mode (one strand
of fiber connecting the transmit transceiver to the receive
transceiver of the board) and see if the yellow LED flash goes away.
If it does the problem is off-board.
If the yellow LED continues to flash, replace the circuit pack.
24
Loss of cell
delineation (LCD)
On board ATM framer chip is not able to frame cells based on the
cell header.
Reset the board (reset board UUCSS).
If the error persists, replace the board.
Table 10-93. Error type 1281 Aux Data and repair procedures — Continued
Aux
Data
Alarm
Description
Repair procedure
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...