Maintenance Object Repair Procedures
555-233-123
10-938
Issue 4 May 2002
Table 10-343.
TEST #6 NPE Crosstalk Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1000
ABORT
System resources for this test are not available. The ISDN-PRI
link may be up and servicing calls. First obtain the ISDN-PRI
link number (lnk-no) from the Communication-Interface Links
form by issuing display communication-interfaces links.
Then, determine the status of the ISDN-PRI link via status link
lnk-no. If the link is in-service, this test aborts. Therefore, to run
this test, the link must be busied out. No new ISDN-PRI calls
can be made while the link is in the busied-out state.
1. If the test must be run, busyout the link.
2. Retry the command.
1001
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1002
ABORT
The system could not allocate time slots for the test. The system
may be under heavy traffic conditions or it may have time slots
out-of-service due to TDM-BUS errors. Refer to TDM-BUS
(TDM Bus) Maintenance to diagnose any active TDM-BUS
errors.
1. If the system has no TDM-BUS errors and is not handling
heavy traffic, repeat the test at 1-minute intervals a
maximum of 5 times.
1003
ABORT
The system could not allocate a tone receiver for the test. The
system may be oversized for the number of Tone Detectors
present or some Tone Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer
to TTR-LEV (TTR Level) Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer
to TONE-PT (Tone Generator) Maintenance
documentation.
3. If neither condition exists, retry the test at 1-minute intervals
a maximum of 5 times.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...