Maintenance Object Repair Procedures
555-233-123
10-1510
Issue 4 May 2002
2049
(cont’d.)
FAIL
Refer to the “Replacing Defective SPE Circuit Packs” section in
Chapter 6 to understand how to correctly replace the
Duplication-Interface circuit pack.
■
If none of the four red LEDs are lit AND if this is the fifth
attempt to clear the problem (the Standby SPE Processor,
Standby SPE Memory, and both Duplication Interface
circuit packs have been replaced), escalate the problem.
9. Issue the refresh spe-standby command to put the Standby
SPE in Standby Mode. This command may have to be issued
multiple times. If the refresh spe-standby command
successfully completes 5 times without the Standby SPE
becoming labeled “standby” on the status system form, wait
20 minutes. This does not include cases where the command
completes with the terminal message line errors “Refresh not
successful; use ‘display errors’ to check for STBY-SPE
errors” or “Cannot interrupt Standby SPE while entering
maintenance mode; please try later.” Issue the refresh
spe-standby command once more.
10. Repeat the test.
11. Issue the test spe-standby long command to thoroughly
test all Standby SPE components.
Table 10-572.
TEST #318 Shadow Link Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...