test packet-control
Issue 4 May 2002
8-465
555-233-123
test packet-control
This command performs hardware diagnostic tests on the specified packet-control
circuit pack.
Feature Interactions
The reset packet-control test (#586) does not run on the active packet-control.
This test is part of the standby packet-control test sequence, illustrated in the
screen output section below.
Action/
Object
Qualifier
Qualifier Description
Logins
Defaults
Feature
Interactions
test
packet-
control
location
short
long
repeat
number
clear
schedule
Applies only to duplicated configurations: if simplex,
parameter is not used and thus is not valid; if
duplicated, “location” represents the carrier in which
the packet-control resides (1A or 1B).
Option for a brief series of nondestructive diagnostic
tests.
Option for a longer, more comprehensive series of
both destructive and nondestructive diagnostic
tests.
How many times each test in the sequence is
repeated (1-100)
This option causes the test sequence (short or long)
to repeat until the alarm (if any) is cleared or a
single test in the sequence fails.
1
Command is validated and then a scheduling form
displays to schedule execution of the command.
The command is then placed in the command
queue and is executed at the specified time. The
information displayed by the command is sent to the
system printer instead of the screen.
2
Examples:
test packet-control
test packet-control A
test packet-control B
test packet-control 1A
test packet-control 1B
test packet-control a short
test packet-control a s repeat 5
test packet-control b s r 5
test packet-control b long clear
test packet-control b l r 25
1
If no alarms are registered against the maintenance object then the test sequence is run only once. The long
clear option forces a clear of all alarms if no errors are encountered during testing. The short clear option only
clears alarms pertinent to tests in the short sequence.
2
Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
nms
Simplex:
location
optional,
cabinet=1,
carrier A.
Duplex:
cabinet=1,
no default
for the
carrier.
See below
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...