MAPD-BD (MAPD Interface Circuit Pack TN802)
Issue 4 May 2002
10-1055
555-233-123
g. Error Type 513: transient hardware problem.
Aux Data:
1. If the same Error Type/Aux Data value occurs more than once in a
24 hour period, the circuit pack should be replaced. See
before removing the circuit pack.
If the MAPD board detects only one of these hardware problems, then the
error is resolved when none of these faults are detected for 10 minutes.
h. Error Type 514: LAN External RAM Error; hardware fault in the PPE
external RAM, used for message buffering to and from the Packet Bus.
This error should not occur regularly.
1. If this error occurs 10 times within 30 minutes, replace the circuit
pack. See
‘‘Shutting down NT on the TN802’’
before removing the
circuit pack.
i. Error Type 769: Transmit FIFO Underflow (threshold is 3 errors within 10
minutes); the circuit pack cannot find the “end of frame” bit when
transmitting a frame to Packet Bus.
1. Clear the alarm using the following command sequence:
a. busyout board UUCSS
b. reset board UUCSS
c. test board UUCSS long clear
d. release board UUCSS
2. If the error recurs within 10 minutes, replace the circuit pack. See
‘‘Shutting down NT on the TN802’’
before removing the circuit pack.
j. Error Type 770: unable to Write LAN Translation RAM (threshold is 2 errors
within 10 minutes); a call is aborted because there are no available
translation RAM locations for the call connection attempt.
1. Clear the alarm using the following command sequence:
a. busyout board UUCSS
b. reset board UUCSS
c. test board UUCSS long clear
d. release board UUCSS
2. If the error recurs within 10 minutes, replace the circuit pack. See
‘‘Shutting down NT on the TN802’’
before removing the circuit pack.
4352
External RAM failure
4353
Internal RAM failure
4355
Internal ROM failure
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...