Maintenance Object Repair Procedures
555-233-123
10-504
Issue 4 May 2002
Error Log Entries and Test to Clear Values
Note:
a. As previously described, the DATA-CON is not directly accessible via a
system technician command so there is no Test to Clear value that can be
used to directly clear errors and alarms raised against the DATA-CON.
However, since the DATA-CON and the DATA-CHLs share the same set of
tests (that is, test the same set of hardware, firmware, and software),
DATA-CON errors and alarms are accompanied by DATA-CHL errors and
alarms.
Therefore, the strategy to clear DATA-CON errors and alarms is to first clear all
DATA-CHL errors and alarms. After DATA-CHL errors and alarms have been
cleared, allow about 60 minutes for maintenance software to run internally and to
automatically clear the DATA-CON errors and alarms.
System Technician-Demanded Tests: Descriptions
and Error Codes
Because the DATA-CON uses the same set of tests as the DATA-CHLs, refer to
the “System Technician-Demanded Tests: Descriptions and Error Codes” in the
DATA-CHL (Network Control Data Channel) Maintenance documentation for a
description of the tests and their associated error codes.
Table 10-184.
Network Control Driver Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear
Value
(a)
0
1
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
none
1
Local Loop Back Test (#111)
MINOR
ON
none
257
Any
Remote Maintenance Loop Around
Test (#109)
MINOR
ON
none
513
Crosstalk Test (#110)
MINOR
ON
none
769
Any
Dual Port RAM Test (#108)
MINOR
ON
none
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...