Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-178
Issue 4 May 2002
continuous
Display updates as new
messages enter the trace
buffer (FIFO). This option is
most useful in conjunction
with “auto-page.” The
command terminates only
when canceled by the user.
LIFO
Newest message displayed
first.
FIFO
Messages displayed in the
order received.
[ auto-page ]
The screen will
automatically page when
full. Used in combination
with continuous (above),
provides a way to “watch”
as messages arrive.
schedule
Report sent to printer.
Command is validated and
then a scheduling form
displays to schedule
execution of the command.
The command is then
placed in the command
queue and is executed at
the specified time. The
information displayed by
the command is sent to the
system printer instead of
the screen.
1
Examples:
list mst continuous
list mst continuous
auto-page
list mst LIFO
list mst from 222 count 7
1
Refer to the Report Scheduler and System Printer feature specification for more details.
Action/
Object
Qualifier
Qualifier Description
Logins
Defaults
Feature
Interactions
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...