Maintenance Object Repair Procedures
555-233-123
10-1000
Issue 4 May 2002
1019
ABORT
Another Test call is in progress.
1. Issue list isdn-testcall to locate the test call.
2. Issue status isdn-testcall to find out the duration and
start time of the test call.
3. Issue clear isdn-testcall to stop the test call from running.
1020
ABORT
There is a problem with DS1 Interface Circuit Pack.
1. Refer to the DS1-BD (DS1 Trunk circuit pack).
1024
ABORT
Maintenance/Test Digital Port in use.
1. Wait until yellow and green LEDs are turned off on the
Maintenance/Test circuit pack.
2. Retry the test.
1113
ABORT
The signaling link has failed. Therefore, the system cannot
send any messages on behalf of this trunk.
1. Check the results of Test #255 (Signaling Link State
Check Test).
1114
ABORT
The signaling link is in a transitional state.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1116
ABORT
The switch could not appropriately change the ISDN service
state.
1. Determine if a call is active on this DS1 ISDN Trunk (use
status trunk).
2. If not, check the Error and Alarm Logs for problems with
this ISDN-TRK (DS1 ISDN Trunk) MO.
1117
ABORT
ISDN B-channel maintenance message is already
outstanding.
1. Wait two minutes. Then try again.
1118
ABORT
Far-end of ISDN trunk is not administered.
1. Check the administration of the far-end ISDN trunk.
2. Issue status trunk.
3. Try the test again.
Table 10-363.
TEST #258 ISDN TEST Call — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...