Maintenance Object Repair Procedures
555-233-123
10-1842
Issue 4 May 2002
Figure 10-101.
TN464C/D DS1 Option Jumpers
Figure 10-102.
TN464C/D DS1 Option Jumpers (Continued)
The option switch located on the component side of the TN464E/F circuit pack
must be set correctly.
shows how to configure the
circuit pack for 24-channel or 32-channel DS1. The channel selection must match
the parameters administered on the corresponding DS1 Circuit Pack Form. (US
applications use 24 Channels.)
Backplane Connectors
24/32 Channel Selector
75/120 Ohm Selector
Top
Bottom
Faceplate
TN464C/D
Insert the jumpers into the blocks
so as to join the center row of
pins and the row designating the
desired options.
120 OHM
32 CHNL
24 CHNL
75 OHM
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...