UDS1-BD (UDS1 Interface Circuit Pack)
Issue 4 May 2002
10-1879
555-233-123
Table 10-675.
TEST #140 Red Alarm Inquiry Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
2000
ABORT
Response to the test was not received within the allowable time
period. This may be due to hyperactivity. Error Type 1538 in the
error log indicates hyperactivity. The hyperactive circuit pack is
out of service and one or more of the following symptoms may
be exhibited.
1. The UDS1-BD tests (such as Test #138 and Test #139) are
aborting with error code 2000.
2. The tests run on the ports of this circuit pack are returning a
no board result.
3. A busyout or a release has no affect on the test results.
4. A list config command shows that the circuit pack and the
ports are properly installed.
NOTE:
When hyperactivity occurs, the circuit pack is isolated
from the system, and all of the trunks for this circuit pack
are placed into the out of service state. The system will
try to restore the circuit pack within 15 minutes. When no
faults are detected for 15 minutes, the UDS1 interface
circuit pack is restored to normal operation. All of the
trunks for the UDS1 interface circuit pack are then
returned to the in service state. Hyperactivity is often
caused by the associated facility. In such a case, faults
(such as slips, misframes, or blue alarms) would be
entered in the error log. In addition, many hardware
errors would be logged against the associated trunk
circuits. If the facility is OK and the error occurs again
after 15 minutes, replace the circuit pack.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...