
Maintenance Object Repair Procedures
555-233-123
10-498
Issue 4 May 2002
14
16
40
2000
2003
2004
FAIL
Codes 40, 41: Remote Maintenance Looparound Test failed
because data was corrupted.
Codes 2000, 2003, and 2004: Remote Maintenance Looparound
Test failed because data was lost.
Test cannot indicate which DATA-CHL is defective.
1. Check dial plan to ensure data channel extensions are set up
as local extensions, not as remote or UDP extensions.
2. Determine if links exist on DATA-CHLs (status link).
3. Execute tests #110 and #111 in the Short Test Sequence for
the target DATA-CHL to determine which actions to take,
based on the results below.
■
Both Test results are PASS: Arbitrarily chosen DATA-CHL
is probably defective.
1. Run Short Test Sequence for each DATA-CHL
not in use.
2. Note the test results for Tests #110 and #111
for each DATA-CHL.
3. Remove DATA-CHLs (remove data-module
ext) where Test results #110 and #111 were
both FAIL.
4. Replace the Netcon or NetPkt circuit pack at
earliest convenience.
■
Only one test result is FAIL for any other DATA-CHLs not in
use: TDM Bus is probably defective.
■
Test #110 result is FAIL and Test #111 result is PASS (for
DATA-CHL): Defective RDM Bus or Tone-Clock board.
1. Check for TDM bus alarms or errors
(TDM-BUS) and/or Tone-Clock circuit pack
alarms or errors (TONE-BD, TONE-PT, and
TDM-CLK).
2. If there are no errors or alarms, the target
DATA-CHL, or Netcon or NetPkt circuit pack
are probably defective: refer to steps in 3.a
above.
3. If there are errors or alarms, refer to
Maintenance documentation to clear the
alarms and errors.
4. Repeat the test.
Table 10-182.
TEST #110 Data Channel Crosstalk Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...