Maintenance Object Repair Procedures
555-233-123
10-1210
Issue 4 May 2002
Error Log Entries and Test to Clear Values
Notes:
a. This error type indicates a disagreement between the switch and the
terminal adapter at the other end of the connection with regard to the ISDN
call state of the PRI Endpoint Port. This switch automatically tries to
recover by clearing the call (that is, the call is torn down). The status
pri-endpoint <extension> command can be used to determine the state
of the port.
When running the Short Test Sequence of tests, pay close attention to the
results of the Call State Audit Test (#257).
Table 10-450.
PRI Endpoint Port Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test port PCSSpp sh r 1
1 (a)
Any
None
test port PCSSpp sh r 1
15 (b)
Any
Audit and Update Test
(#36)
18 (c)
0
busyout pri-endpoint
<extension> busyout
port <PCSSpp>
WARNING
OFF
release pri-endpoint
<extension> release port
<PCSSpp>
129 (d)
None
WARNING
OFF
test port PCSSpp sh r 1
130 (e)
None
WARNING
ON
test port PCSSpp sh
257 (f)
Any
None
test port PCSSpp sh r 1
513 (g)
Any
None
WARNING
OFF
test port PCSSpp sh r 1
76 9 (f)
Any
None
test port PCSSpp sh r 1
1281 (h)
Any
Conference Circuit
Test (#7)
MINOR
ON
test port PCSSpp l r 4
1537 (i)
Any
NPE Crosstalk Test
(#6)
MINOR
ON
test port PCSSpp l r 3
1793 (j)
Any
None
test port PCSSpp sh r 1
3073 (k)
Any
Service State Audit
(#256)
test port PCSSpp sh r 2
3585 (l)
Any
None
None
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...