CLSFY-PT (Call Classifier Port)
Issue 4 May 2002
10-417
555-233-123
Tone Detector Audit/Update Test (#43)
A sanity audit is performed on the CLSFY-PT (Call Classifier Port).
Table 10-156.
Tone Detector Audit/Update Test (#43)
Error
Code
Test
Result
Description/Recommendation
none
ABORT
The system was not able to allocate all the resources needed
for this test.
1. Wait 1-minute, and repeat the command a maximum of 5
times.
2000
ABORT
Response to the test request was not received within the
allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
FAIL
Hardware audit failed.
1. Run the short test sequence via the test port PCSSpp
sh r 1 command.
2. If the problem persists, the system is still operating
properly but system capacity will be reduced. In order to
restore system performance to normal, replace the
CLSFY-BD (Call Classifier circuit pack) containing the
defective CLSFY-PT (Call Classifier Port).
PASS
The (CLSFY-PT) Call Classifier Port has passed the sanity
inquiry.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...