Maintenance Object Repair Procedures
555-233-123
10-168
Issue 4 May 2002
Aux Data Error Codes and Recommended Repair
Procedures
Table 10-55.
Aux Data Error Codes and Recommended Repair Procedures
Aux
Data
Description/Recommendation
9000
through
9031
CARD-MEM [386 systems] errors.
Check and resolve CARD-MEM [386 systems] errors and alarms.
30001
through
30054
Tape [286 systems] errors.
Check and resolve TAPE [286 systems] errors and alarms.
32001
Internal system error.
1. Check other ANNOUNCE errors and take corrective action. If there
are no other ANNOUNCE errors, do the following:
2. Retry the command at two minute intervals a maximum of three times.
3. If the save/restore announcements command fails, escalate the
problem.
32002
Announcement circuit pack is in use.
1. Retry the command at two minute intervals a maximum of three times.
2. If the save/restore announcements command fails, escalate the
problem.
32003
Announcement port is in use.
1. Wait for all Announcement ports to become available.
2. Enter the save/restore announcements command.
32004
There are no announcements recorded on the Announcement Circuit
Pack. The save announcements command is not allowed to prevent the
destroying of the announcement file on tape [286 systems] or on the
memory card [386 systems].
32005
Integrated announcement circuit pack is not present. The Announcement
Circuit Pack is not inserted, or it is defective.
1. Enter the list config command to check for the presence of the circuit
pack in the system.
2. If the Announcement Circuit Pack is present, use the test board
PCSS command to check the status of the Announcement Circuit
Pack.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...