Maintenance Object Repair Procedures
555-233-123
10-466
Issue 4 May 2002
If more than one CONFIG error is logged with an Aux Data of 1 at the same
time, investigate any EXP-INTF (Expansion Interface) errors before
proceeding.
Once the Port circuit pack location has been determined from
, use the list configuration all command to determine if the circuit
pack is inserted. If not, insert the pack. If the circuit pack has already been
inserted but the error persists, replace the circuit pack.
Table 10-171.
System Configuration Error Log Entries
Error Type
Aux Data
Port Circuit Pack Location
1
0
GAMUT Circuit Pack
1
1
1
GAMUT Circuit Pack
2
0
1E01
2
1
2E01
2
2
3E01
3
0
1E02
3
1
2E02
3
2
3E02
4
0
1E03
4
1
2E03
4
2
3E03
5
0
1E04
5
1
2E04
5
2
3E04
6
0
1E05
6
1
2E05
6
2
3E05
7
0
1E06
7
1
2E06
7
2
3E06
8
0
1E07
8
1
2E07
8
2
3E07
9
0
1E08
9
1
2E08
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...