Maintenance Object Repair Procedures
555-233-123
10-1474
Issue 4 May 2002
Table 10-557.
TEST #7 Conference Circuit Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at one-minute intervals a maximum of 5
times.
1000
ABORT
System resources required to run this test are not available. The
port may be busy with a valid call and therefore unavailable for
certain tests. You must wait until the port is idle (yellow LED if off)
before retesting.
1. If the port is idle, retry the command at one-minute intervals a
maximum of 5 times.
1004
ABORT
The port was seized by a valid call during the test and the test has
been aborted. You must wait until the port is idle (yellow LED if off)
before retesting.
1. Retry the command at one-minute intervals a maximum of 5
times.
2. If the test continues to abort and the port is not in use, escalate
the problem.
1020
ABORT
The test did not run due to an already existing error on the specific
port or a more general circuit pack error.
1. Examine Error Log for existing errors against this port or the
circuit pack and attempt to diagnose the already existing error.
2000
ABORT
Response to the test request was not received within the allowable
time period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at one-minute intervals a maximum of 5
times.
Any
FAIL
The NPE of the tested port did not conference the tones correctly.
This causes noisy and unreliable connections.
1. Retry the test.
2. If the Test continues to fail then replace the circuit pack.
PASS
The port can correctly conference multiple connections.
User-reported troubles on this port should be investigated using
other port tests and examining the Error Log.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...