DUPINT (Duplication Interface Circuit Pack)
Issue 4 May 2002
10-709
555-233-123
Duplication Interface Circuit Pack Background
Test Query (#271)
This test queries the Duplication Interface circuit pack for the results of its
background tests. The response indicates the results of the last time the following
background tests were run:
■
ROM Checksum Test: This test verifies the correctness of the Duplication
Interface circuit pack firmware.
■
RAM Test: This tests verifies that the RAM on the Duplication Interface
circuit pack is functioning properly.
Table 10-261.
TEST #271 Duplication Interface Circuit Pack
Background Test Query Test
Error
Code
Test
Result
Description/Recommendation
1000
ABORT
System resources required to run this test are not available.
2000
ABORT
Response to the test request was not received within the
allowable time period.
2033
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
2008
2009
2010
FAIL
One or both background tests failed on the Duplication
Interface circuit pack. Error Code 2008 means the ROM test
failed. Error Code 2009 means the RAM test failed. Error Code
2010 means both tests failed.
1. Follow the procedures for replacing Common Control
circuit packs and replace the Duplication Interface circuit
pack.
2. Rerun the test.
NO
BOARD
The Duplication Interface circuit pack has failed to reply to
handshaking from either the active Maintenance/Tape
Processor (in the case of Duplication Interface circuit pack A) or
from Duplication Interface circuit pack A (in the case of
Duplication Interface circuit pack B).
1. Refer to NO BOARD description for the Duplication
Interface Circuit Pack Status Query Test (#315).
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...