Maintenance Object Repair Procedures
555-233-123
10-1318
Issue 4 May 2002
1339
ABORT
The test could not run on the standby Packet Interface because
the standby SPE is unavailable.
1. Refer to the STBY-SPE maintenance documentation for
information on why a standby SPE may be unavailable and
what repair actions should be taken. The status syst
1screen indicates the state of the standby SPE.
Unavailability may be caused by a variety of reasons, such
as the setting the SPE-SELECT switches on the DUPINT
circuit packs to the position of the active SPE, a failure of
the DUPINT circuit pack, or loss of power on the standby
SPE. The
SPE SELECT SWITCH
field on the status syst
1 screen displays
spe a
or
spe b
if the SPE-SELECT
switches are in the a or b position, respectively.
2000
ABORT
Response to the test request was not received within the
allowable time period. Retry the command at 1-minute
intervals, a maximum of 3 times.
2500
ABORT
Internal system error
1. Retry the command.
NO
BOARD
The Packet Interface is not detected as being physically
present.
1. Reboot the system, then retry the command. If the NO
BOARD indication persists, replace the TN2401/TN794
NetPkt circuit pack.
Table 10-488.
TEST #888 Active-Standby Peer Link Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...