Maintenance Object Repair Procedures
555-233-123
10-900
Issue 4 May 2002
PASS
Hybrid Circuit and Conference Circuit Test passed. The hybrid
circuitry is transmitting properly.
1. If complaints still exist, investigate by using other port
tests, and by examining the station, wiring, and
connections.
0
NO
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is
inserted, an incorrect board is inserted, or an insane board is
inserted.
1. Check to ensure that the board translations are correct.
Use the list config command, and resolve any problems
that are found.
2. If the board was found to be correctly inserted in step 1,
issue busyout board.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue test board long. This should re-establish the
linkage between the internal ID and the port. If this is not
the case, dispatch to check to ensure that there is a valid
board inserted.
Table 10-326.
TEST #57 Hybrid Circuit and Conference Circuit Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...