Maintenance Object Repair Procedures
555-233-123
10-40
Issue 4 May 2002
2100
ABORT
Could not allocate the necessary system resources for this test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Any
FAIL
The NPE of the tested port did not conference the tones
correctly. This causes noisy and unreliable connections.
1. Replace the circuit pack.
PASS
The port can correctly conference multiple connections.
User-reported troubles on this port should be investigated by
using other port tests and by examining station, trunk, or external
wiring.
Table 10-15.
TEST #7 Conference Circuit Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page