DS1-BD (DS1 Interface Circuit Pack)
Issue 4 May 2002
10-645
555-233-123
PASS
No Red alarm is detected on DS1 Interface circuit pack.
0
NO
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is inserted,
an incorrect board is inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use
the add ds1 UUCSS command to administer the DS1
interface if it is not already administered.
2. If board was already administered correctly, check the error
log to determine if the board is hyperactive. If this is the case,
the board is shut down. Reseating the board will re-initialize
the board.
3. If the board was found to be correctly inserted in step 1,
issue the busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and
the port.
Table 10-237.
TEST #140 Red Alarm Inquiry Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page