Maintenance Object Repair Procedures
555-233-123
10-1800
Issue 4 May 2002
For a system with a TN768, TN780 or TN2182 Tone-Clock Circuit Pack:
Notes:
a. Refer to XXX-BD for descriptions of these tests.
b. Refer to TONE-PT for descriptions of these tests.
c. Refer to TDM-CLK for descriptions of these tests.
d. This test runs only on the standby Tone-Clock circuit pack in a Port
Network with duplicated Tone-Clocks (High or Critical Reliability systems).
The circuit pack must be a TN780 with firmware version 2 or above or a
TN2182.
Clock Health Inquiry Test (#46)
This inquiry reads special data stored in memory to determine if this Tone-Clock
circuit pack had a loss of any of three clock types:
■
SYSCLK
■
SYSFM
■
SYSDCLK
If this data indicates this Tone-Clock circuit pack had a loss of any of these clocks,
the inquiry reports FAIL. In addition, if TDM-CLK error 1 is at threshold, this test
will FAIL. TDM-CLK error 1 indicates a suspect clock is at the edge of its specified
frequency. If the circuit pack did not have a loss of clock or TDM-CLK error 1 at
threshold, the inquiry reports PASS.
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/
ND
1
1
D = Destructive; ND = Nondestructive
SAKI Reset Test (#53) (a)
X
Clock Health Inquiry Test (#46)
X
X
Control Channel Loop Around Test (#52) (a)
X
X
Tone Generator Crosstalk Test (#90) (b)
X
Tone Generator Transmission Test (#40) (b)
X
X
Tone Generator Audit/Update (#41) (b)
X
X
TDM Bus Clock Circuit Status Inquiry Test (#148)
(c)
X
X
TDM Bus Clock Slip Inquiry (#149) (c) (e)
X
X
TDM Bus Clock PPM Inquiry Test (#150) (c)
X
X
TDM Bus Clock Parameter Update Test (#151) (c)
X
X
Board Type Check Test (#574) (c)
X
X
Standby Reference Health Check Test (#651) (c,d)
X
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...