
PKT-CTRL (Packet Control Circuit Pack)
Issue 4 May 2002
10-1289
555-233-123
2073
FAIL
After being downloaded from the tape, the Packet Control
circuit pack does not contain valid downloadable firmware in its
memory.
1. Retry the command.
2. If the tests fails again with the same error code, then the
tape may contain corrupted Packet Control circuit pack
firmware. Replace the tape and retry the command. If the
test still fails with this error code, then replace the Packet
Control circuit pack.
2102
FAIL
As the Packet Control circuit pack firmware was being
downloaded from system tape, a block of data could not be
read from the tape. This indicates a problem with the tape unit,
and not with the Packet Control circuit pack.
1. Test the TAPE with the long option and with a repeat
option of 3. If any of the tests fail, or if there are any tape
alarms, refer to the TAPE Maintenance documentation
and follow the recommended repair procedures. If a tape
problem is detected and then fixed, then retry the reset
command.
2. If no tape problem was detected in the previous step, then
there may be a problem with the area on the tape where
the Packet Control circuit pack firmware resides. Replace
the tape cartridge and then retry the reset command.
2500
FAIL
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
PASS
The reset command passed and the Packet Control circuit
pack is operational. If the Packet Control circuit pack was
busied-out, it needs to be released (via the release
packet-control C command) before it can be considered in
service.
Table 10-482.
TEST #586 Packet Control Reset Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...