Maintenance Object Repair Procedures
555-233-123
10-624
Issue 4 May 2002
PASS
Communication with this circuit pack is successful.
0
NO
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is inserted,
an incorrect board is inserted, or an insane board is inserted.
1. Ensure that board translations are correct. Use add ds1
UUCSS to administer the DS1 interface if it is not already
administered.
2. If the board was already administered correctly, check the
error log to see if the board is hyperactive. If this is the case,
the board is shut down. Reseating the board to re-initialize.
3. If the board was correctly inserted in step 1, use busyout
board.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and
the port.
Table 10-232.
TEST #52 Control Channel Looparound Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page