Maintenance Object Repair Procedures
555-233-123
10-908
Issue 4 May 2002
1004
ABORT
The port was seized by a valid call during the test. The test
has been aborted. Use display port PCSSpp determine the
station extension number of the port. Use the status station
to determine the service state of the port. If the service state
indicates that the port is in use, then the port is unavailable for
certain tests. (Refer to the “Status Commands” section in
Chapter 10, “Maintenance Commands and Trouble-Clearing
Aids” for a full description of all possible states.) You must wait
until the port is idle before retesting. Attendants are always in
use (off-hook), if the handset is plugged in and the port is not
busied out.
1. Retry the command at one-minute intervals a maximum of
5 times.
2. If the test continues to abort and the port is not in use,
escalate the problem.
2000
ABORT
Response to the test request was not received within the
allowable time period.
FAIL
Internal System Error.
1. Retry the command at one-minute intervals a maximum of
5 times.
Table 10-330.
TEST #61 Hybrid Line Audits Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...