STBY-SPE (Standby SPE)
Issue 4 May 2002
10-1553
555-233-123
2025
(cont’d.)
ABORT
■
If the red LED on the Standby SPE Memory circuit pack is
on, replace the Standby SPE Memory circuit pack as
described in
Chapter 6, ‘‘Reliability Systems: A Maintenance
and proceed with Steps 10, 11, and 12.
■
If the red LED on the carrier A Duplication Interface circuit
pack is on, replace the carrier A Duplication Interface circuit
pack as described in
Chapter 6, ‘‘Reliability Systems: A
and proceed with Steps 11, 12, and 13.
■
If none of the three red LEDs is on AND if this is the first
attempt to clear the problem, replace the Standby SPE
Processor circuit pack as described in
and proceed with Steps 10,
11, and 12.
■
If none of the three red LEDs is on AND if this is the second
attempt to clear the problem (that is, the Standby SPE
Processor circuit pack has already been replaced), replace
the Standby SPE Memory circuit pack as described in
Chapter 6, ‘‘Reliability Systems: A Maintenance Aid’’
and
proceed with Steps 10, 11, and 12.
■
If none of the three red LEDs is on AND if this is the third
attempt to clear the problem (that is, the Standby SPE
Processor and Standby SPE Memory circuit packs have
already been replaced), replace the carrier A Duplication
Interface circuit pack as described in
and proceed with Steps 10,
11, and 12.
Table 10-578. Test Result Error Codes Associated with the Standby SPE — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...