PDMODULE, TDMODULE (Data Module)
Issue 4 May 2002
10-1199
555-233-123
Table 10-448.
TEST #175 Data Module Internal Loop Around Test
Error
Code
Test
Result
Description/Recommendation
1000
ABORT
Could not get translation information for port.
1. Verify that port circuit is administered.
2. Wait one minute and attempt the test again.
3. If the test continues to abort and the port is not in use,
escalate the problem.
1005
ABORT
This test is not applicable to the given hardware configuration.
1. This abort message can be ignored.
1020
ABORT
Internal Software Error.
1. Retry the command at one-minute intervals a maximum of 5
times.
1030
ABORT
Internal software group identifier for data module not valid.
1. Verify that port circuit is administered correctly.
2. If administration data correct, escalate the problem.
1031
ABORT
Extension number not valid.
1032
ABORT
Extension number not correct length.
1. Verify that the data module extension is administered
correctly.
2. If the administration data is correct, escalate the problem.
1071
ABORT
No auxiliary port on Netcon circuit pack available to test with.
1. Check that the Netcon data channels are administered (the
list data-modules command should show at least one
Netcon-type data module).
2. Test the Network Control (Netcon) circuit pack using the
test data-module command for the Netcon circuit pack.
3. If administration data is correct, escalate the problem.
2000
ABORT
Data module disconnected.
1. Verify that the data module is powered (power LED on).
2. Make sure data module is connected to the building wiring.
Check for faulty wiring and faulty data module.
3. Retry the command at one-minute intervals a maximum of 5
times.
4. Replace the Data Module and repeat the test.
5. If the test continues to abort, replace the Digital Line circuit
pack and repeat the test.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...