Maintenance Object Repair Procedures
555-233-123
10-52
Issue 4 May 2002
Battery Feed Test (also called Port Diagnostic
Test) (#35)
The battery feed chip provides power to the telephone equipment, signaling,
rotary dial pulsing, transmission, and balance. This test checks the signaling and
switchhook capabilities of the battery feed chip by terminating the port, applying
battery and detecting the resulting current.
For the TN746B, Test #35 does not actually run and instead always returns PASS.
Test #35 operates in the normal manner for TN746.
Table 10-20.
TEST #35 Battery Feed Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1000
ABORT
System resources required to run this test are not available.
The port may be busy with a valid call. This result is also
reported for the system’s Music-On-Hold port when it is
off-hook, which it usually is.
1004
ABORT
The port was seized by a valid call during the test. The test has
been aborted.
1. Use the display port PCSSpp command to determine the
station extension.
2. Use the status station command to determine the service
state of the port.
3. If the port is in use, wait until the port is idle and retry the
command at 1-minute intervals a maximum of 5 times.
1005
ABORT
The test was aborted due to a configuration problem. This test
may not be applicable, or it may be disruptive to terminal
equipment other than a voice terminal (for example, the
modem pool member or Music On Hold).
1018
ABORT
The test has been disabled via administration. The default for
the
Test
field on the station form is y. Determine why this
field has been set to
n
on this station (this may be due to the
ringing application test 48, that can be customer or terminal
disturbing).
1. To enable the test for a particular station being tested,
enter change station extension and set the
Test?
field
on the station from
n
to y.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...