STBY-SPE (Standby SPE)
Issue 4 May 2002
10-1545
555-233-123
2015
ABORT
The Standby SPE Maintenance/Tape Processor did not reply to an
Active SPE request to hold the Standby SPE Processor reset. The
communication path between the Active SPE and the Standby SPE
Maintenance/Tape Processor may have failed, or the Standby SPE
Maintenance/Tape Processor may have failed. Follow the
procedures described for Error Code 2024 in the STBY-SPE
section.
2016
2017
ABORT
The Active SPE attempted to put the Standby SPE into Maintenance
Mode, but did not receive notification from the Standby SPE
Maintenance software that it successfully entered Maintenance
Mode OR, once in Maintenance Mode, the Standby SPE sent a
request to the Active SPE to have the Active SPE conduct a portion
of a test in the Standby SPE’s behalf, but the Standby SPE did not
receive a response to its request. In either case, the communication
path between the Active SPE and the Standby SPE may have
failed. Follow the procedures described for Error Code 2024 in the
STBY-SPE section.
2018
ABORT
The test requires that a maintenance activity request be made to the
Standby SPE; however, the request cannot be made because the
Standby SPE is busy processing a previous maintenance activity
request.
1. Issue refresh spe-standby to force the Standby SPE to
Standby Mode. This command may have to be issued multiple
times. If refresh spe-standby successfully completes 5 times
without the Standby SPE becoming labeled “standby” on the
status system form, wait 30 minutes. This does not include
cases where the command completes with the terminal
message line errors “Refresh not successful; use ‘display
errors’ to check for STBY-SPE errors” or “Cannot interrupt
Standby SPE while entering maintenance mode; please try
later.” Issue refresh spe-standby once more.
2. Repeat the test.
3. Issue test spe-standby long to thoroughly test all Standby
SPE components.
2019
ABORT
A translation save on the Standby SPE was not carried out because
the Shadow Link Test failed. (The Shadow Link Test was done to
verify the integrity of the translation data on the Standby SPE.)
1. Check for Memory Shadowing Link errors and alarms. Refer to
SHDW-LNK (Memory Shadowing Link) Maintenance
documentation and follow the prescribed procedures.
Table 10-578. Test Result Error Codes Associated with the Standby SPE — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...