DS1-BD (DS1 Interface Circuit Pack)
Issue 4 May 2002
10-669
555-233-123
2000
ABORT
Response to the test was not received within the allowable time
period. This may be due to hyperactivity. Error type 1538 in the
error log indicates hyperactivity. The hyperactive circuit pack is
out of service and one or more of the following symptoms may be
exhibited.
1. The DS1-BD tests (such as test 138 and test 139) are
aborting with error code 2000.
2. The tests run on the ports of this circuit pack are returning a
no board result.
3. A busyout or a release command has no affect on the test
results.
4. A list config command shows that the circuit pack and the
ports are properly installed.
NOTE:
When hyperactivity occurs, the circuit pack is isolated from
the system, and all of the trunks for this circuit pack are
placed into the out of service state. The system will try to
restore the circuit pack within 15 minutes. When no faults
are detected for 15 minutes, the DS1 interface circuit pack
is restored to normal operation. All of the trunks for the
DS1 interface circuit pack are then returned to the in
service state. Hyperactivity is often caused by the
associated facility. In such a case, faults (such as slips,
misframes, or blue alarms) would be entered in the error
log. In addition, many hardware errors would be logged
against the associated trunk circuits. If the facility is OK
and the error occurs again after 15 minutes, escalate this
problem.
Table 10-245.
TEST #1210 CSU Equipment Loopback Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...