AC-POWER
Issue 4 May 2002
10-9
555-233-123
Notes:
a. Refer to “POWER” for a description of this test.
b. Refer to “CARR-POW” for a description of this test.
c. Refer to “EMG-XFER” for a description of this test.
d. Refer to “CABINET” for a description of this test.
e. Refer to “EXT-DEV ADMIN? N” or “EXT-DEV ADMIN? Y” for a description
of this test.
f. Refer to “RING-GEN” for a description of this test.
AC Power Query Test (#78)
This test queries the Maintenance/Tape Processor in a PPN in a system without
High or Critical Reliability, the Duplication Interface circuit pack in a High or Critical
Reliability system PPN, or the EPN Maintenance circuit pack in an EPN
multicarrier cabinet system for the status of AC power to the switch. In a
DC-powered system, this test should never fail.
Emergency Transfer Query Test (#124) (c)
X
X
ND
Cabinet Temperature Query Test (#122) (d)
X
X
ND
External Alarm Lead Query Test (#120) (e)
X
X
ND
Analog Ring Generator Initialization Test (#117) (f)
X
X
ND
Analog Ring Generator Query Test (#118) (f)
X
X
ND
1
D = Destructive, ND = Non-destructive
Table 10-4.
System Technician-Demanded Tests: AC-Power — Continued
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...